Posted today
Pay
Not stated
Location
Remote-Friendly, United States
Remote
H-1B approvals FY2025: 25 (USCIS)
Initial H-1B petitions USCIS approved for ANTHROPIC PBC (CA) in fiscal year 2025, from the H-1B Employer Data Hub. It says what the employer has done, not whether a given role will be sponsored.
Official sourceJobs at employers with H-1B approvals in the United States
Skills this role screens for
Opens on Anthropic's site. Sign in first and we keep it in your pipeline.
Still studying?Paid internships in the United States open nowAbout the role
About Anthropic
Anthropic’s mission is to create reliable, interpretable, and steerable AI systems. We want AI to be safe and beneficial for our users and for society as a whole. Our team is a quickly growing group of committed researchers, engineers, policy experts, and business leaders working together to build beneficial AI systems.
The work
Training and serving frontier AI models requires compute infrastructure at a scale and density that pushes past what conventional data center designs were built to handle. The loads involved are large enough — and arrive fast enough — that utility supply alone often can't meet the need on the timeline required, and the step-load behavior of large accelerator clusters creates power-quality and ride-through demands that conventional backup-generation designs weren't built for. Anthropic's Data Center Infrastructure team is responsible for solving that problem: delivering facilities that can be energized early, ride through grid disturbances, and present a well-behaved load at the point of interconnection (POI).
As a Data Center Power Generation & Microgrids Engineer, you'll own the behind-the-meter generation and storage architecture for Anthropic's data center portfolio. That means the on-site generation fleet — reciprocating engine gensets, gas turbines, fuel cells — and the battery energy storage systems that buffer load steps and provide ride-through. It means the microgrid layer that ties them together: islanding and resynchronization, black-start, load-shedding, and generation dispatch. And it means the grid side: interconnection studies and agreements, IEEE 1547/2800 compliance, and power quality at the point of interconnection. You'll also own our temporary- and bridging-generation strategies — the plans that let a site energize and start serving load before permanent utility service is available, and transition cleanly once it is.
This is a deeply cross-functional role. You'll work closely with colleagues across the infrastructure team on where and how generation and storage tie into the site electrical distribution, controls, and SCADA, and with our hardware and compute teams to understand the load characteristics you're designing against. You'll be Anthropic's technical counterpart to on-site generation providers, BESS integrators, utilities, and ISOs/RTOs. Expect roughly 20–35% travel for design reviews, factory witness testing, and site startup.
The work
On-site generation engineering
•
Own Anthropic's behind-the-meter generation architecture across the portfolio — prime-mover selection and sizing (reciprocating engines, gas turbines, fuel cells), paralleling topology, redundancy, fuel systems, and emissions controls — and maintain the generation basis of design and technical specifications that build partners and generation providers design against
•
Set the day-one vs. day-N plant sizing and expansion strategy — what the plant needs on day one so it can be expanded or augmented later, and how to add units, storage, or a grid tie to a system already running
•
Characterize the data center load for external generation partners — step changes, ramps, oscillation, fault behavior, and non-IT load — so providers can size and tune their plant against the real duty
•
Model generation response against the load profile of large-scale ML training — step-load acceptance, block loading, transient frequency and voltage response, load rejection — and set the acceptance criteria (e.g., per ISO 8528-5) that generation packages are tested against
•
Develop temporary- and bridging-generation strategies that deliver early site energization ahead of permanent utility service, including the sequencing, protection, and controls changes needed to transition from temporary to permanent power without stranding equipment or capacity
•
Ensure generation designs meet NFPA 37, NFPA 110 where the plant provides emergency or legally required standby power, fuel-gas and fuel-storage codes (e.g., NFPA 54, NFPA 30), and applicable emissions requirements, and coordinate with environmental and permitting counterparts on the technical inputs to air permits
Energy storage & microgrid architecture
•
Size and specify battery energy storage systems for ride-through, step-load buffering, and power-quality support — including cell chemistry and enclosure selection, inverter selection (grid-forming vs. grid-following), UL 9540 listing, UL 9540A large-scale fire test data, and NFPA 855 installation requirements — and own the thermal and fire-protection interfaces
•
Define the site microgrid topology and operating modes — grid-parallel, islanded, and black-start — and the transition logic between them, including load-shedding schemes, resynchronization criteria, and the conditions under which the site separates from and reconnects to the utility
•
Specify the functional requirements for the microgrid controller — generation dispatch, set-point coordination across rotating and inverter-based sources, mode management — and drive its implementation, testing, and integration into site SCADA and the electrical power monitoring system (EPMS)
•
Help define the protection and control requirements for generation and storage sources so that interconnection protection, anti-islanding, and source-transfer schemes are consistent from the generator terminals through the point of interconnection
Grid interconnection & power quality
•
Lead the technical side of utility interconnection for sites with on-site generation or storage — interconnection applications, studies, and agreements, ISO/RTO processes, IEEE 1547/2800 compliance, and interconnection protection
•
Own power quality at the point of interconnection — flicker per IEEE 1453, harmonics per IEEE 519, voltage regulation, reactive-power and power-factor requirements — and design the generation, storage, and filtering mitigations needed to keep the site within its interconnection limits under real training-load behavior
•
Run or critically review the power-system studies that support interconnection and microgrid design — load flow, short-circuit contribution from rotating and inverter-based sources, transient stability, motor-starting and step-load studies, and electromagnetic-transient studies where inverter controls matter
Vendor diligence & delivery
•
Lead technical due diligence on on-site generation providers, BESS integrators, and microgrid-controller vendors — evaluating equipment and controls on engineering merit, stress-testing performance and availability guarantees, and reviewing proposed architectures against Anthropic's basis of design
•
Define the technical performance terms in energy-services agreements with on-site generation providers — availability, power quality, ramp, and ride-through, each with a definition, meter, test protocol, and acceptance criteria — working with energy commercial and legal counterparts
•
Review and disposition design packages, submittals, shop drawings, and deviation requests from generation providers and their EPCs, and hold partners to Anthropic's reliability and maintainability requirements
•
Support commissioning of generation, storage, and microgrid systems — witnessing factory and site acceptance tests, defining and observing integrated systems tests (islanding, resynchronization, black-start, load-step), and resolving field issues against design intent
•
Manage concurrent generation and microgrid scopes across multiple sites, and contribute to the continuous improvement of Anthropic's generation and interconnection design standards as the portfolio and the technology both evolve
You may be a good fit if you
•
Have 10+ years of engineering experience in power generation, microgrids, battery energy storage, or utility interconnection, with substantial time spent on on-site or distributed generation for mission-critical, data center, or large industrial loads, and deep hands-on delivery experience in at least…
From Anthropic's own careers system (Greenhouse).
insiderOne never charges students to apply. Never pay anyone for an internship. Check an offer you received
This role screens for AI/ML. Sit a ten-minute live challenge, get a signed receipt, and the employer sees it verified on your application instead of claimed.
Prove it, then applySCOUT, an AI agent, not a person, answers from this ad, and says so when the ad doesn't cover it. No account, and nothing you type here is kept.
More data roles
insiderOne University
Get certified for roles like this: Data Analytics Associate
Free, about 2 hours, ending in a project a person reviews and a certificate any employer can check. Put it on this application and every one after it.
Start the certificationWhat is in it